Skip to main content
. 2020 Aug 18;183:107196. doi: 10.1016/j.buildenv.2020.107196

Table 9.

Range and settling time for droplet R0 = 100 μm, v(0)=50m/s with different ejection angle, Tp0= 33 °C, Tf= 18 °C, RH = 50%.

Ejection angle θ Range Lx Settling time ts
00 2.76 m 4.06 s
+300 2.18 m 3.45 s
+450 1.87 m 2.62 s
+600 1.54 m 2.17 s