Table 4.
Mean loss of contrast sensitivity, expressed in logarithmic units, from photopic to mesopic lighting conditions (LC) and under glare conditions in mesopic LC.
|
| ||||||||||
| Loss Photopic to Mesopic LC | Loss Mesopic to Mesopic with glare LC | |||||||||
| Spatial Frequency (cpd) | 1.5 | 3 | 6 | 12 | 18 | 1.5 | 3 | 6 | 12 | 18 |
| IOL1 | 0.051 | 0.105 | 0.227 | 0.406 | 0.569 | 0.096 | 0.23 | 0.233 | 0.452 | 0.256 |
| IOL2 | 0.021 | 0.129 | 0.185 | 0.400 | 0.358 | 0.165 | 0.121 | 0.154 | 0.217 | 0.331 |
| IOL3 | 0.030 | 0.140 | 0.221 | 0.521 | 0.433 | 0.167 | 0.139 | 0.229 | 0.099 | 0.206 |
| P (ANOVA) | 0.69 | 0.62 | 0.69 | 0.69 | 0.27 | 0.17 | 0.04 | 0.75 | 0.02 | 0.64 |
| P ( t -test)1–2* | 0.43 | 0.59 | 0.17 | 0.77 | 0.25 | 0.13 | 0.01 | 0.71 | 0.27 | 0.84 |
| P ( t -test)1–3* | 0.53 | 0.31 | 0.60 | 0.34 | 0.41 | 0.20 | 0.05 | 0.84 | 0.04 | 0.81 |
| P ( t -test)2–3* | 0.92 | 0.64 | 0.60 | 0.62 | 0.75 | 0.98 | 0.77 | 0.85 | 0.30 | 0.67 |
| IOL1, Bioline Yellow Accurate; IOL2, Physiol H65C/N; IOL3, BioAcryl60125; cpd, cycles per degree P-value comparing all three IOL groups with one-way analysis of variance; *P-value comparing IOL groups in couples with Student's t-test | ||||||||||