Skip to main content
. 2020 Jul 26;20(15):4157. doi: 10.3390/s20154157

Table 4.

Comparison of the signal preprocessing methods of the proposed apnea system with the previous studies.

Reference Signal Preprocessing Methods
Feature-Learning-Based Systems
Our Study Bandpass Filtering + Z-score Normalization
Singh and Majumder [15] Bandpass Filtering + Continuous Wavelet Transform +
Zerocenter Normalization
Wang et al. [16] FIR Filtering + R-peaks Detection +
RR Interval Calculation + Median Filtering +
Cubic Interpolation
Li et al. [17] Bandpass Filtering + R-peaks Detection +
RR Interval Calculation + Median Filtering +
Interpolation
Feature-Engineering-Based Systems
Sharma and Sharma [12] Bandpass Filtering + R-peaks Detection +
RR Interval Calculation + QRS Complex Extraction + Zero Padding
Song et al. [13] Filter-Bank-Based R-peaks Detection +
RR Interval Calculation + Median Filtering +
EDR Derivation
Varon et al. [14] Notch Filtering + DC Component Remove +
Up Sampling + R-peaks Detection +
R-peaks Correction + RR Interval Calculation +
EDR Derivation

FIR: Finite impulse response; DC: Direct current; and EDR: ECG-derived respiration.