Comparison between corrosion rates (vcor-in µm/year) for the OPS sample.

Corrosive Environment Scan Rate
0.5 mV/s 10 mV/s
Rainwater - 26.80
Black Sea water 114 51.17
Fire extinguishing solution 517 376.00