Skip to main content
. 2020 Sep 28;38(1):e14374. doi: 10.1111/dme.14374

TABLE 1.

Flash glucose monitoring data for the whole cohort in March and May 2020 (N = 572)

March 2020 May 2020 Median difference P comparing March 2020 and May 2020
Average glucose, mmol/l 9.6 (8.5 to 10.9) 9.3 (8.1 to 10.4) –0.4 (–1.1 to 0.3) <0.001
sd glucose, mmol/l 3.6 (3.0 to 4.3) 3.5 (2.8 to 4.0) –0.2 (–0.5 to 0.2) <0.001
IQR glucose, mmol/l 5.0 (4.1 to 6.0) 4.8 (3.9 to 5.8) –0.2 (–0.8 to 0.4) <0.001
Coefficient of variation glucose, % 37 (33 to 42) 37 (33 to 42) –0.1 (–3.2 to 2.9) 0.420
Low glucose events, number/14 days 7 (3 to 12) 7 (3 to 14) 1 (–2 to 3) 0.003
Low glucose event duration, min 90 (60 to 120) 92 (65 to 127) 3 (–26 to 34) 0.061
% time below target range: <3.9 mmol/l 3 (1 to 6) 3 (1 to 7) 0 (–1 to 2) 0.005
% time in range: 3.9–10.0 mmol/l 53 (41 to 64) 56 (45 to 68) 3 (–4 to 10) <0.001
% time above range: >10.mmol/l 42 (29 to 56) 39 (25 to 51) –3 (–11 to 3) <0.001
Number of daily scans 10 (7 to 15) 10 (7 to 15) 0 (–2 to 1) 0.074
% flash glucose monitoring data captured 94 (90 to 97) 93 (88 to 96) –1 (–4 to 1) <0.001
Estimated HbA1c <0.001
mmol/mol 61 (53 to 69) 58 (50 to 66) –2 (–7 to 2)
% 7.7 (7.0 to 8.5) 7.5 (6.7 to 8.2) –0.2 (–0.6 to 0.2)
Time in range target met (>70%), n/N (%) 93/572 (16) 122/572 (21) NA 0.001
Hypoglycaemia target met (<5%), n/N (%) 365/572 (64) 332/572 (58) NA 0.004
Time in range and hypoglycaemia targets met, n/N (%) 55/572 (9.6) 65/572 (11) NA 0.261

Data are median (IQR), unless otherwise indicated.

Abbreviation: IQR, interquartile range.