TABLE 2.

Persistence of bacteriophage phi 6 within an ATS matrix on porous hospital curtainsa,b

Virus Surface Matrix AH (g/m3) (°C, % RH) Decay ratec r2 D value (min [log10]) Time to no detection (reduction at last sampling point detected [log10]) Source or reference no.
Phi 6 TC ATS 3.0 (18, 20) 0.11/day 0.72 30 42 days (5.40 at 35 days) Current data
Phi 6 UC ATS 3.0 (18, 20) 0.10/day 0.71 30 42 days (5.27 at 35 days) Current data
Phi 6 TC ATS 14.4 (26, 57) 0.65/h 0.71 <30 (2) N/Ad (4.91 at 6 h) Current data
Phi 6 UC ATS 14.4 (26, 57) 0.71/h 0.49 <30 (3) N/A (5.19 at 5 h) Current data
HCoV 229 Cotton gauze Growth medium 10.1–12.9 (21, 55–70) N/A N/A N/A 12 h (3) 34
HCoV OC43 Cotton gauze Growth medium 10.1–12.9 (21, 55–70) N/A N/A N/A 1 h (3) 34
SARS-CoV-1 Cotton gown Growth medium N/A (20, N/A)e N/A N/A N/A 1 day (6) 44
a

One treated with zinc pyrithione (TC) and one untreated (UT).

b

Human coronavirus studies on other porous surfaces are presented for comparison. Limited comparison data from the literature for three coronaviruses are also presented.

c

Decay rates for current data based upon model predictions graphed in Fig. 1 and 2 and expressed in log10.

d

N/A means that no data were provided or that the experiment was not extended until there was no detection.

e

AH was not calculated because RH was not provided.