Skip to main content
. 2020 Jul 15;37(9):3827–3838. doi: 10.1007/s12325-020-01432-9

Table 3.

Mean values of dark-adapted electroretinogram (ERG), light-adapted ERG, and 30-Hz flicker ERG (F-ERG) responses assessed in control subjects (C) and in patients with Joubert syndrome with (JS-RD group) or without (JS-NRD group) retinal dystrophy

Dark-adapted ERG Light-adapted ERG F-ERG
a-wave b-wave a-wave b-wave A (log µV)
IT (log ms) A (log µV) IT (log ms) A (log µV) IT (log ms) A (log µV) IT (log ms) A (log µV)
C (N = 25)
 Mean 13.271 46.125 28.875 71.542 11.042 12.933 28.813 29.355 34.063
 SD 0.766 2.597 2.849 4.688 1.444 2.083 1.131 3.852 2.288
JS-RD (N = 16)
 Mean 15.613 26.081 41.738 38.110 13.069 8.819 34.047 16.469 15.806
 SD 3.111 10.369 10.333 20.099 2.786 4.486 8.827 10.498 9.138
AV vs C
 f(1,40) 13.101 86.142 35.053 64.561 9.392 16.332 8.692 31.444 92.022
 p  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001
JS-NRD (N = 8)
 Mean 15.275 29.325 37.938 43.066 15.000 8.625 29.188 18.425 20.613
 SD 2.647 14.336 5.421 18.930 4.520 4.211 1.624 5.129 14.102
AV vs C
 f(1,32) 11.951 33.133 45.644 50.182 15.252 15.283 0.543 41.543 22.392
 p 0.002  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001 0.469  < 0.001  < 0.001
AV vs JS-RD
 f(1,23) 0.073 0.402 0.944 0.345 1.692 0.954 2.330 0.241 1.032
 p 0.795 0.531 0.343 0.567 0.208 0.341 0.141 0.626 0.322

ANOVA statistical evaluation by one-way analysis of variance between groups. p values less than 0.01 were considered as statistically significant (in bold)

N number of eyes, SD standard deviation, IT implicit time, A amplitude, ms milliseconds, µV microvolt