Skip to main content
. 2020 Jun 24;93:20190725. doi: 10.1259/bjr.20190725

Table 4.

Diagnostic performances of knee pathology in 2D TSE and 3D CAIPIRINHA MRI

Parameters Meniscal tear Ligament tear Cartilage abnormality
2D 3D 2D 3D 2D 3D
Sensitivity 83.9% (26/31) 90.3% (28/31) 100% (6/6) 100% (6/6) 80.0% (20/25) 88.0% (22/25)
Specificity 69.2% (9/13) 69.2% (9/13) 94.7% (36/38) 94.7% (36/38) 78.9% (15/19) 78.9% (15/19)
Accuracy 79.5% (35/44) 84.1% (37/44) 95.5% (42/44) 95.5% (42/44) 79.5% (35/44) 84.1% (37/44)
PPV 86.7% (26/30) 87.5% (28/32) 75.0% (6/8) 75.0% (6/8) 83.3% (20/24) 84.6% (22/26)
NPV 64.3% (9/14) 75.0% (9/12) 100% (36/36) 100% (36/36) 75.0% (15/20) 83.3% (15/18)

NPV, negative predictive value; PPV, positive predictive value.

a