Table 2.

The most common dose–volume parameters used for reporting partial-breast irradiation. (Adapted according [84])

Parameter Definition/calculation
Reference dose related
VPD Absolute volume irradiated by the prescribed dose
V1.5xPD Absolute volume irradiated by 1.5 x the prescribed dose
DNR—dose non-uniformity ratio (only for brachytherapy) V1.5xPD/VPD
DHI—dose homogeneity index (only for brachytherapy) (VPD − V1.5xPD)/VPD
Target related
VPTV Volume of the PTV
Vxx Percentage of PTV receiving xx% of the PD
CI—coverage index (V100) V100/100
COIN—conformal index PTVPD/VPTV PTVPD/VPD
Dxx Percentage dose that covers xx% of the PTV
OAR related
Dmean Mean dose in organ
VxGy Relative volume x receiving Gy
Vxx Percentage of organ receiving xx% of the PD
Dxcm3 Relative dose given to most exposed x cm3 of organ

PD prescribed dose, PTVPD volume in planning target volume receiving at least the PD