Comparison of Clinical Performance of the Elecsys Anti–SARS-CoV-2 Antibody Assay Assuming 3%, 5%, or 10% Disease Prevalence

PCR Positive 3% 5% 10%
0-13 Days, % ≥14 Days, % 0-13 Days, % ≥14 Days, % 0-13 Days, % ≥14 Days, %
Sensitivity 77.50 94.74 77.50 94.74 77.50 94.74
Specificity 100 100 100 100 100 100
Positive predictive value 100 100 100 100 100 100
Negative predictive value 99.31 99.84 98.83 99.72 97.56 99.42
Accuracy 99.33 99.84 98.88 99.74 97.75 99.47