Energy analysis results for a reference plant.

Variable Value Unit
Electrolysis and DAC Total energy requirements of reference plant 435 MW
Of which electricity is 315 MW
Overall energy efficiency 16.5%
Gasification Coal requirement of gasifier 212,014 tonne/year
Total energy requirements of reference plant 324 MW
Of which electricity is 39 MW
Overall energy efficiency 22.1%
Coal equivalent of thermal energy required for reference plant Spray dryer 62,039 tonne/year
DAC 53,140 tonne/year