Skip to main content
. 2020 Sep;61(9):1388–1396. doi: 10.2967/jnumed.119.239327

TABLE 3.

Comparison of Results Obtained from Analysis of Image Quality in LD PET Images and Predicted Images in PIS and PSS for Validation Dataset

Dataset SSIM PSNR RMSE
Validation
 PIS 0.97 ± 0.02 34.60 ± 1.08 0.18 ± 0.02
 PSS 0.98 ± 0.01 38.25 ± 0.66 0.15 ± 0.03
 LD 0.84 ± 0.04 29.00 ± 0.92 0.40 ± 0.03
 P (PIS vs. PSS) 0.022 0.019 0.016
 P (PIS vs. LD) 0.037 0.021 0.036
 P (PSS vs. LD) 0.042 0.025 0.030
Test
 PIS 0.96 ± 0.03 31.70 ± 0.75 0.18 ± 0.04
 PSS 0.97 ± 0.02 37.30 ± 0.71 0.17 ± 0.01
 LD 0.82 ± 0.15 29.92 ± 0.71 0.41 ± 0.04
 P (PIS vs. PSS) 0.031 0.024 0.018
 P (PIS vs. LD) 0.040 0.036 0.041
 P (PSS vs. LD) 0.041 0.031 0.031