Table 3.

Predictive Accuracy of FENO50 and Blood Eosinophil Measurements for Assessing Airway Eosinophilia in Stable COPD Patients

FENO50
Sputum Eosinophils AUC 95% CI P value Cut Point (ppb) Sensitivity (%) Specificity (%) PPV (%) NPV (%)
>3% (n=8) 0.69 0.45–0.93 0.097 29.5 63 91 56 93
>2% (n=13) 0.59 0.39–0.79 0.350 20.6 50 75 44 79
Blood Eosinophils (absolute count)
Sputum Eosinophils AUC 95% CI P value Cut Point (cells ×109/L) Sensitivity (%) Specificity (%) PPV
(%)
NPV
(%)
>3% (n=8) 0.84 0.65–1.02 0.003 0.316 75 98 86 95
>2% (n=13) 0.82 0.68–0.96 <0.001 0.204 77 76 53 91
Blood Eosinophils (relative percentage)
Sputum Eosinophils AUC 95% CI P value Cut Point (%) Sensitivity (%) Specificity (%) PPV (%) NPV (%)
>3% (n=8) 0.80 0.58–1.01 0.008 3.5 75 84 46 95
>2% (n=13) 0.78 0.63–0.93 0.003 2.5 77 63 42 89

Abbreviations: AUC, area under the receiver operating characteristic curve; CI, confidence interval; FENO50, fractional exhaled nitric oxide measured at an exhalation flow rate of 50 mL/s; ppb, parts per billion; PPV, positive predictive value; NPV, negative predictive value.