Table 4.
Author | RA Complications | CM Complications |
---|---|---|
Khlopas et al. 2019 | - | - |
Cho et al. 2019 | 2 Deep infections (two-stage revision) | 1 Deep infection (two stage revision) 2 Aseptic Loosening (implant revision) 2 Polyethylene wear (implant revision) 1 Knee instability (implant revision) (p=0.48) |
Yang et al. 2017 | 2 Deep infection (two-stage revision) No cases of radiolucent lines | 2 Deep infection (two-stage revision) 1 Knee instability (implant revision) (p=0.27) 6 Radiolucent lines, non-progressive (p<0.001) |
Merchand et al. 2017 | - | - |
Liow et al. 2016 | 1 Superficial wound infection 1 Early infection (washout and liner exchange) 1 Lateral pain in tibial component due to malposition after aborted procedure (revision tibial component) 1 Deep vein thrombosis 3 Abortion of robot procedure (2 technical error and 1 robot error) | 1 Deep vein thrombosis |
Song et al. 2013 | 2 Superficial wound infections 1 Seroma at pin site 2 patellar tendon abrasion 1 Skin rash (conservative treatment) | 2 Superficial wound infections 1 Incisional skin sloughing |
Song et al. 2011 | - | - |
Park et al. 2007 | 1 Superficial wound infection 1 Patellar tendon rupture 1 Patellar dislocation 1 Peroneal injury | - |
Siebert et al. 2002 | 3 Skin irritation at pin site (conservative treatment) 1 Complication due to defective registration marker, full correction achieved by converting to a manual technique | - |
RA, Robotic-assisted technique; CM, Conventional manual-jig technique.