Table 3:
Correlations (ρ), between parameters (interparameter), and between model coefficients and measured mechanical properties. No significant interparameter correlations were observed, except for a weak correlation between β and k2 (ρ=−0.25). E was significantly correlated with mechanical parameters: for circumferential samples, both μ and β had significant relationships to E, but only μ had a strong correlation (ρ=0.91); similarly for axial samples, μ and k1 were significantly correlated with E, but only k1 had a strong correlation coefficient (ρ=0.79).
Incompressible Demiray (Circumferential) | ||
Interparameter Correlation | ||
ρ | p-value | |
β, μ | 0.01 | 0.94 |
Correlation to Stiffness (E) | ||
ρ | p-value | |
E, β | 0.26 | 0.02 |
E, μ | 0.91 | 0.00 |
Incompressible Demiray + Exponential Fiber (Axial) | ||
Interparameter Correlation | ||
ρ | p-value | |
β, μ | 0.02 | 0.89 |
μ, k1 | −0.06 | 0.56 |
μ, k2 | −0.16 | 0.15 |
β, k1 | 0.11 | 0.30 |
β, k2 | −0.25 | 0.02 |
k1, k2 | −0.06 | 0.57 |
Correlation to Stiffness (E) | ||
ρ | p-value | |
E, μ | 0.43 | 0.00 |
E, β | 0.07 | 0.52 |
E, k1 | 0.79 | 0.00 |
E, k2 | −0.07 | 0.50 |