Skip to main content
. 2020 Sep 1;10:14411. doi: 10.1038/s41598-020-71416-w

Figure 2.

Figure 2

Testing developed SSE determination method and comparing it with the method of AFM force spectroscopy. (a) Influence of air humidity on SSE measurement results obtained with force spectroscopy (normal separation method); (b) influence of air humidity on SSE measurement results obtained with lateral separation method; (c,d) a scheme of the influence of moisture on the probe behavior for the lateral method; (e, f) for the lateral method.