Table 4.
5-fold cross-validation results were generated through the proposed method on the GPCR dataset.
| Testing set | Accuracy (%) | Precision (%) | Sensitivity (%) | MCC (%) | AUC | AUPR |
|---|---|---|---|---|---|---|
| 1 | 83.86 | 81.89 | 85.25 | 72.91 | 0.8853 | 0.7820 |
| 2 | 81.89 | 79.37 | 83.33 | 70.29 | 0.8894 | 0.7493 |
| 3 | 78.74 | 84.75 | 73.53 | 66.35 | 0.8660 | 0.8154 |
| 4 | 85.04 | 88.29 | 79.67 | 74.34 | 0.8998 | 0.8591 |
| 5 | 82.28 | 82.48 | 84.33 | 70.71 | 0.8992 | 0.7993 |
| Average | 82.36 ± 2.39 | 83.35 ± 3.36 | 81.22 ± 4.79 | 70.92 ± 3.04 | 0.8879 ± 0.0138 | 0.8010 ± 0.0407 |