Table 1.

Mean ± standard deviation of the discrepancies at the implant apex and shoulder level and the main axis.

Position Technology Guidance Apex (mm) Shoulder (mm) Axis (°)
x y z x y z
35 SLA S 0.3 ± 0.2 −0.2 ± 0.2 −0.1 ± 0.2 0.1 ± 0.1 −0.2 ± 0.2 −0.1 ± 0.1 1.3 ± 0.9
NS 0.3 ± 0.2 0.1 ± 0.1 −0.1 ± 0.2 0.1 ± 0.1 0.1 ± 0.1 −0.1 ± 0.1 1.6 ± 0.5
FDM S 0.2 ± 0.4 −0.3 ± 0.1 0.1 ± 0.3 0.1 ± 0.2 −0.3 ± 0.1 0 ± 0.1 1.9 ± 0.8
NS 0.3 ± 0.2 −0.1 ± 0.2 0.2 ± 0.3 0.2 ± 0.1 −0.1 ± 0.2 0 ± 0,1 1.9 ± 0.8
37 SLA S 0.1 ± 0.3 −0.1 ± 0.1 0.0 ± 0.2 0.1 ± 0.1 −0.1 ± 0.1 0.0 ± 0,1 1.2 ± 0.6
NS 0.1 ± 0.2 0.0 ± 0.1 0.0 ± 0.2 0.1± 0.1 −0.1 ± 0.1 0.0 ± 0,1 0.8 ± 0.5
FDM S 0.4 ± 0.4 0.0 ± 0.2 −0.1 ± 0.1 0.3 ± 0.1 0.1 ± 0.2 0.0 ± 0.1 1.7 ± 0.9
NS 0.3 ± 0.2 0.1 ± 0.1 0.1 ± 0.2 0.2 ± 0.1 0.1 ± 0.1 0.0 ± 0,1 1.3 ± 0.4

SLA: stereolithography, FDM: fused deposition modeling, S: metal sleeve, NS: no metal sleeve, x: sagittal discrepancies, y: transversal discrepancies, z: vertical discrepancies.