Influence of sonication power, reaction time, concentration of reactants and temperature on the size and morphology of MOF-1s.

Morphology SEMd Sonication power (W) Concentration (M)c t (min)b T (°C)a Entry
Cubes (3D) 423.55 0 0.1 60 50 1
Mixed morphology (mostly rods) 114.37 60 0.1 60 50 2
Rods morphology (1D) 191.64 60 0.1 30 50 3
Mixed morphology 345.00 60 0.5 60 50 4
Mixed morphology 46.65 60 0.1 60 70 5 (MOF-1s)e

aReaction temperature.

bReaction time.

cConcentration of reactants.

dAverage diameter of particles (nm).

eEntry 5 was used to application.