1.0 |
CNT/PDMS (Porous Structure) |
Piezoresistive |
0.25 |
100.0 |
0.588 4
|
[257] |
No blood pressure measurement application.
Not all properties were reported (e.g., hysteresis, stability test).
High limit of detection.
|
2.0 |
CNT@EcoFlex (Buckled Structure) |
Piezocapacitive |
50.0 |
1000 |
230 |
[244] |
No blood pressure measurement application.
Not all properties were reported (e.g., hysteresis, stability test).
High limit of detection.
|
3.0 |
ACNT-Graphene /PDMS (CVD) |
Piezoresistive |
0.0006 |
0.3 |
19.8 |
[259] |
No blood pressure measurement application.
Response time is <16.7 ms. 5
Stability for more than 35,000 loading/unloading cycles. 6
Operating voltage is 0.03 V. 7
Low maximum detection.
|
4.0 |
CNT/PDMS (Patterned Microstructure) |
Piezoresistive |
0.0002 |
59.0 |
15.1 |
[258] |
No blood pressure measurement application.
Performance changed under cycle-test with constant pressure.
Not all properties were reported.
The operating voltage is 10.0 V. 7
|
5.0 |
VACNT/PDMS (T-CVD) |
Piezoresistive |
0.002 |
10.0 |
0.3 and up to 0.7 |
[260] |
Blood pressure measurement application without calibration, need to assess accuracy.
Response time is around 162 ms. 5 Acceptable reproducibility over 5000 cycles of pressure loading/ unloading. 6
|
6.0 |
SWCNTs/PDMS (Silk Molded Microstructure) |
Piezoresistive |
0.0006 |
1.2 |
1.8 |
[272] |
No blood pressure measurement application but heart pulse.
Response time is 10 ms. 5
Stability for around 67,500 loading/unloading cycles. 6
Operating voltage is 2.0 V. 7
|
7.0 |
CB@PU Sponge |
Piezoresistive |
0.091 |
16.4 |
0.068 |
[240] |
No blood pressure measurement application but heart pulse.
Stability for around 50,000 loading/unloading cycles. 6
Response time is 20 ms. 5
|
8.0 |
MWCNT-rGO@PU Foam |
Piezoresistive |
0.0035 |
2.7 |
0.022 |
[256] |
No blood pressure measurement application but heart pulse.
Stability for around 5000 loading/unloading cycles. 6
Response time is < 30 ms. 5
|
9.0 |
SWCNTs/PDMS |
Optical |
1.0 |
- |
0.2 |
[201] |
No blood pressure measurement application.
Response time is 300 ms. 5
No stability test information was reported.
Transparent optical application.
|
10.0 |
CNT/3D Microporous Elastomeric Dielectric Layer |
Piezocapacitive |
0.0001 |
130 |
0.601 |
[194] |
No blood pressure measurement application but heart pulse.
Stability for around 1000 loading/unloading cycles. 6
Operating voltage can be 1.0 V. 7
|
11.0 |
Graphene@PU |
Piezoresistive |
0.009 |
10.0 |
0.26 |
[273] |
No blood pressure measurement application but heart pulse.
Stability for around 10,000 loading/unloading cycles. 6
Not all properties were reported.
|
12.0 |
Graphene (MEMS) |
Piezoresistive |
0.1 |
- |
3.4 × 10−6
|
[274] |
No blood pressure measurement application.
Response Time is 0.9 s. 5
Operating voltage is 2.5 V. 7
Not all properties were reported.
|
13.0 |
Graphene Paper |
Piezocapacitive |
2.0 |
20.0 |
17.2 |
[275] |
No blood pressure measurement application, but heart pulse.
Response time is120 ms. 5
Stability for around 300 loading/unloading cycles. 6
Fabricated by Dip Coating.
|
14.0 |
Graphene Electrode (T-CVD) |
Piezocapacitive |
4.4 × 10−5 (1 mg) |
- |
3.19 |
[247] |
No blood pressure measurement application, but it sounds to be suitable for this application.
The applied voltage is 3.3 V. 7
Stability for around 500 loading/unloading cycles. 6
Response time is 30 ms. 5
|
15.0 |
Graphene (Porous GS) |
Piezoresistive |
0.3 |
10.0 |
0.046 |
[276] |
|
16.0 |
Graphene Electrode |
Piezocapacitive |
8.0 |
- |
6.55 |
[268] |
No blood pressure measurement application.
Stability for around 500 loading/unloading cycles. 6
Response time is 70ms. 5 =
|
17.0 |
Suspended Graphene /Polymer (Heterostructure Membranes) |
Piezocapacitive |
80.0 |
- |
123ZF |
[277] |
|
18.0 |
Graphene Tribotronics |
FET |
1.0 |
- |
0.02 |
[278] |
No blood pressure measurement application.
Stability for around 1700 loading/unloading cycles. 6 =
Response time is 30 ms. 5 =
Operating voltage can be 0.5 V. 7 =
Suitable for electronic skin and touch screen applications.
|
19.0 |
rGO/PANI Wrapped Sponge |
Piezoresistive |
0.1 |
27.0 |
0.152 |
[279] |
No blood pressure measurement application.
Response time is around 96 ms. 5 =
Stability for around 9000 loading/unloading cycles. 6 =
High current output (i.e., ∼300 μA at 1.0 V. 7 =
|
20.0 |
PNIPAm/CMC/ rGO DN Hydrogel |
Thermo-resisitive |
- |
800.0 |
- |
[280] |
|
21.0 |
rGO/PU Sponge |
Piezoresistive |
4.84 × 10−5 (1.1 mg) |
- |
0.21 |
[281] |
No blood pressure measurement application.
Stability for around 10,000 loading/unloading cycles. 6 =
Response time is about 100 ms. 5 =
Not all properties were reported.
|
22.0 |
rGO/PDMS Film (Pattered Micropyramid) |
Piezoresistive |
0.0015 |
1.4 |
5.5 |
[243] |
No blood pressure measurement application.
Response time is 0.2 ms. 5 =
Stability for around 5000 loading/unloading cycles at 100 Pa. 6 =
The applied voltage is 1.0 V. 7 =
|
23.0 |
rGO Films with Continuous Gradient Wrinkles |
Piezoresistive |
0.0042 |
3.0 |
178.0 |
[282] |
No blood pressure measurement application.
Stability for around 1200 loading/unloading cycles. 6 =
Response time is 131 ms. 5 =
Operating Voltage can be 1.0 V. 7 =
|
24.0 |
Large-Scale Polystyrene Ball@rGO Core Shell NPs |
Piezoresistive |
0.003 |
3.0 |
50.9 |
[283] |
No blood pressure measurement application but heart pulse.
Stability for around 20,000 loading/unloading cycles. 6
Response time is 50 ms. 5
Operating Voltage can be 1.0 V. 7
|
25.0 |
Graphene (Electrode Microconformal) |
Piezocapacitive |
4.4 × 10−5 (1 mg) |
- |
7.68 |
[190] |
No blood pressure measurement application but heart pulse.
Stability for around 5000 loading/unloading cycles. 6
The applied voltage is 1.0 mV. 7
Response time is 30ms. 5
|
26.0 |
Integrated Arrays of Air-Dielectric Graphene Transistors |
FET |
0.25 |
3000 |
2.05 × 10−4
|
[270] |
No blood pressure measurement application.
Response Time is 30 ms. 5
Stability for around 1000 loading/unloading cycles. 6
The gate voltage is 25.0 V. 7
|
27.0 |
Graphene Transistor Array (Direct-Contact Tribotronic Planar) |
FET |
0.16 mm−1
|
- |
- |
[269] |
No blood pressure measurement application.
Stability for around 1000 loading/unloading cycles. 6
Response time is 15 ms. 5
Gate voltage can be 2.0 V. 7
|
28.0 |
Graphene (Direct Laser Scribing PDMS) |
Piezoresistive |
0.028 |
- |
480.0 |
[271] |
No blood pressure measurement application.
Stability for around 4000 loading/unloading cycles. 6
Response time is 0.002 ms. 5
Operating voltage can be 5.0 V. 7
|
29.0 |
3D Graphene Film (Fingerprint Like Patterned) |
Piezoresistive |
0.0002 |
75.0 |
110.0 |
[242] |
No blood pressure measurement application but heart pulse.
Stability for around 10,000 loading/unloading cycles. 6
Response time is 30 ms. 5
Operating voltage can be 3.0 V. 7
|
30.0 |
GO (Spray Coating through a Stencil Mask) |
Piezocapacitive |
0.24 × 10−3
|
- |
0.8 |
[192] |
No blood pressure measurement application.
Response time is around 100 ms. 5
Maximum hysteresis is 5.0%@ 1.4 kPa.
Stability for around 100 loading /unloading cycles. 6
|
31.0 |
MoS2/GPN /Ecoflex (T-CVD) |
Piezoresistive |
0.6 |
25.4 |
6.06 |
[284] |
Suitable for blood pressure measurement application.
Stability for around 4000 loading/unloading cycles. 6
Response Time is 200 ms. 5
|
32.0 |
PVA NWs/ Wrinkled Graphene Film |
Piezoresistive |
0.00224 |
- |
28.34 |
[285] |
No blood pressure measurement application.
Stability for around 6000 loading/unloading cycles. 6
The applied voltage is 0.1V. 7
Not all properties were reported.
|
33.0 |
rGO Film/ PDMS Arrays |
Piezoresistive |
0.0013 |
225.0 |
1.71 |
[238] |
No blood pressure measurement application.
Stability for around 5000 loading/unloading cycles. 6
Response time is 6 ms. 5
Operating Voltage can be 1.0 V. 7
|
34.0 |
P(VDF-TrFe) /rGO |
Piezoresistive |
0.0012 |
- |
15.6 |
[251] |
No blood pressure measurement application.
Stability for around 100,000 loading/unloading cycles. 6
Response time is 5 ms. 5
The applied voltage is 1.0 mV. 7
|
35.0 |
PEDOT:PSS /PUD (Pattered Micropyramid) |
Piezoresistive |
0.023 |
8.0 |
10.3 |
[176] |
No blood pressure measurement application but heart pulse.
Response time 0.2 s. 5
Stability 800 loading/unloading cycles. 6
Applied Voltage is 0.2 V. 7
|
36.0 |
PVDF-HFP/PEDOT (3D Electrospun Nanofibers) |
Piezoresistive |
0.001 |
30.0 |
13.5 |
[286] |
No blood pressure measurement application but heart pulse.
Stability for around 10,000 loading/unloading cycles. 6
Response time is around 0.4s. 5
The applied voltage is 1.0 V. 7
|
37.0 |
P(VDF-TrFe) (Electrospun Nanofiber) |
Piezoresistive |
0.0001 |
0.012 |
0.00041 |
[287] |
|
38.0 |
[PPy@PVA-co-PE] and POE Nanofibers |
Piezoresistive |
0.0013 |
7.0 |
1.24 |
[288] |
Suitable for blood pressure measurement application.
Stability for around 250 loading/unloading cycles. 6
Operating voltage can be 2.0 V. 7
|
39.0 |
Au NWs/Tissue Paper (Dip-Coating) |
Piezoresistive |
0.013 |
- |
1.14 |
[289] |
No blood pressure measurement application but heart pulse.
The operating voltage is 1.5 V 7 with low energy consumption that is <30 µW.
Response time is <17 ms. 5
High Stability for around 50,000 loading/unloading cycles.
|
40.0 |
Au NP Densely Packed µNW based Pressure |
Piezoresistive |
0.025 |
|
0.0801 |
[290] |
No blood pressure measurement application.
Stability for around 6000 loading/unloading cycles. 6
Response time is <270 ms. 5
Not all properties were reported.
|
41.0 |
Ag IDEs and PdOx NP (Percolative Metal NP Arrays) |
Piezoresistive |
0.0005 |
1.0 |
0.13 |
[248] |
No blood pressure measurement application.
Stability for around 500 loading/unloading cycles. 6
Hysteresis induced by a 1.0 kPa applied pressure showed a shift of 0.012% from the initial value.
|
42.0 |
AG NWs (Ag NW Flower) |
Piezocapacitive |
0.0006 |
115.0 |
1.54 |
[195] |
No blood pressure measurement application.
Stability for around 5000 loading/unloading cycles. 6
Not all properties were reported.
|
43.0 |
Ge/Si Core/shell NW PSR (OLED) |
FET |
1.0 |
- |
42.7 |
[210] |
No blood pressure measurement application.
Response time is 1 ms.5
Operating voltage is 10 V. 7
Not all properties were reported.
|
44.0 |
MOF (CuTCNQ) |
Piezoresistive |
0.00073 |
3.0 |
6.25 |
[249] |
Suitable for blood pressure measurement application.
Stability for around 10,000 loading/unloading cycles. 6
Response time is 10 ms. 5
Operating voltage can be 1.0 V. 7
MOF is relatively expensive.
|
45.0 |
C-MOF/PANIF @PU Sponge |
Piezoresistive |
0.001 |
60.0 |
158.26 |
[291] |
No blood pressure measurement application, but heart pulse.
Stability for around 15,000 loading/unloading cycles. 6
Response time is < 22 ms. 5
|
46.0 |
C-MOF-5 Derived Porous Carbon |
Piezoresistive |
0.02 |
1.0 |
15.63 |
[292] |
No blood pressure measurement application.
Stability for around 2000 loading/unloading cycles. 6
Response time is < 65 ms. 5
Operating voltage is 3.0 V. 7
|
47.0 |
MXenes Nanosheets (Ti3C2Tx) |
Piezoresistive |
0.0102 |
30.0 |
0.55 |
[200] |
No blood pressure measurement application.
Stability for around 10,000 loading/unloading cycles.6
Response time is less than 11 ms.5
Operating voltage is 0.01 V.7
|
48.0 |
MXenes Nanosheets (Ti3C2) |
Piezoresistive |
- |
0.351 |
7.5 |
[250] |
No blood pressure measurement application.
Stability for around 4000 loading/unloading cycles. 6
Response time is < 30 ms. 5
Operating voltage is 1.0 V. 7
|
49.0 |
Pt-coated Polymeric Nanofibers (Nanohair) |
Piezoresistive |
0.005 |
- |
11.35 |
[293] |
No blood pressure measurement application.
Response time is 50 ms. 5
Stability for around 10,000 loading/unloading cycles. 6
|
50.0 |
ITO (3D Printed Mold) |
Piezocapacitive |
0.003 |
4.0 |
1.62 |
[294] |
No blood pressure measurement application but heart pulse.
Stability for around 1000 loading/unloading cycles. 6
Operating voltage can be 3.0 V. 7
Response time is < 10 ms. 5
|
51.0 |
Ag Flexible Piezoelectret-Based Pressure Sensor |
Piezoelectric |
- |
2.5 |
15.0 |
[295] |
No blood pressure measurement application.
Stability for around 36,000 loading/unloading cycles with constant pressure. 6
Perfluoro (alkoxy alkane) electret.
Not all properties were reported.
|
52.0 |
ITO/PDMS (Pattered micro-pyramid) |
Piezocapacitive |
0.003 |
20.0 |
0.55 |
[296] |
No blood pressure measurement application.
Response time is 1.0 s. 5
Stability for around 10,000 loading/unloading cycles. 6
The gate voltage is higher than 5.0 V. 7
|
53.0 |
Ag NWs (Embedded PDMS Electrode with Microarray Structure) |
Piezocapacitive |
0.003 |
5.0 |
2.94 |
[297] |
No blood pressure measurement application.
Stability for around 1000 loading/unloading cycles. 6
Response time is less than 50 ms. 5
Not all properties were reported.
|