Skip to main content
. 2020 Aug 6;13(16):3470. doi: 10.3390/ma13163470

Table 2.

Parameters and levels selected through preliminary experiments.

S. No. Parameters Units Range Levels
1 2 3 4 5
Coded Values −2 −1 0 1 2
1. Pulse-on
Time (A)
(µs) 108–124 108 112 116 120 124
2. Pulse-off
Time (B)
42–58 42 46 50 54 58
3. Spark Gap
Voltage (C)
(volts) 24–72 24 36 48 60 72
4. Wire
Feed rate (D)
(m/min) 4–12 4 6 8 10 12