Table 3.

The chilldown efficiencies, ηCD, for different coating layers and the percentage increase in ηCD over the base case, 0L.

Pin (psig) 0L 1L 2L 3L 4L
ηCD (%) 40.6 42.3 47.5 54.0 47.7
80 Percent increase in ηCD (%) 0 4.2 17.2 33.0 17.5
ηCD (%) 42.3 46.8 52.6 59.3 64.0
60 Percent increase in ηCD (%) 0 10.5 24.4 40.1 51.3
ηCD (%) 37.5 56.1 63.6 62.2 70.3
40 Percent increase in ηCD (%) 0 49.7 69.7 66.1 87.6
ηCD (%) 38.3 49.7 59.5 70.8 80.0
20 Percent increase in ηCD (%) 0 30.0 55.5 85.0 109.1