Skip to main content
. 2020 Aug 24;5(35):22402–22410. doi: 10.1021/acsomega.0c02846

Table 1. Relevant Published Various Methods of PCB Detection.

method linear range (M) detection limit (M) reference
gas chromatography–mass spectrometry 6.8 × 10–11 to 8.6 × 10–7 9.2 × 10–12 (5)
liquid chromatography–mass spectrometry   1.6 × 10–10 (37)
surface-enhanced Raman spectroscopy aptamer sensor 3.3 × 10–8 to 1.0 × 10–6 3.3 × 10–8 (38)
electrochemical aptamer-carbon nanotube biosensor 1.9 × 10–7 to 8.8 × 10–6 1.2 × 10–8 (18)
electrochemical aptamer/Au biosensor 6.8 × 10–10 to 6.8 × 10–7 3.4 × 10–11 (13)
electrochemical oxide graphene/β-cyclodextrin polymer 1.0 × 10–12 to 1.0 × 10–5 5.0 × 10–13 (39)
electrochemical β-cyclodextrin/400 nm-diameter gold electrode 1.0 × 10–15 to 1.6 × 10–14 2.1 × 10–16 (40)
electrochemical ATA/BDD biosensor 1.0 × 10–15 to 1.0 × 10–11 3.2 × 10–16 this work