Table 2. Difference (F1) and Similarity (F2) Factors of Each Release Profile for MB Release from the Coated Implant Design.

curve 1 curve 2 F1 F2
H100 H50L50 97.60 33.24
H50L50 H40L60 84.09 18.60
H50L50 H35L30P30 89.46 16.20
H40L60 H35L35P30 16.82 49.29