TABLE I:

Estimated Saturation Times

Method Microbubble Concentration (MBs per mL blood) Time to 90% MB perfusion (seconds) MB perfusion time adjusted to common blood concentration (seconds)
Dencks et al. [12] 5.56 x 106 101 150
Christensen-Jeffries et al. [7] 5.56 x 106 139 206
Hingot et al. [6] 3.75 x 106 230.4 230.4
ULM CAM saturation 5.6 x 107 21.4 319
Confocal wash-in 5.6 x 107 13 193
Markov-chain (unweighted) 5.6 x 107 1.6 24.5
Markov-chain (distance-weighted) 5.6 x 107 3.5 51.8
Markov-chain (centroid-weighted) 5.6 x 107 5.9 88.3
Markov-chain (distance- and centroid-weighted) 5.6 x 107 12.2 182