Skip to main content
. Author manuscript; available in PMC: 2021 Sep 1.
Published in final edited form as: Anal Bioanal Chem. 2020 Jul 14;412(24):6611–6624. doi: 10.1007/s00216-020-02797-0

Table 1:

Quantification of glucose and lactate dynamics in rat striatum.

Glucose
Stimulation Parameters Maximum Concentration (mM) Peak Time (sec) Rate of Increase (mM/sec) Fall Under Baseline (mM) Time Below Baseline (sec) Total Range (mM) Rate of Decrease (mM/sec)
30 Hz 120 Pulses 0.7 ± 0.2 6.2 ± 0.6 0.11 ± 0.04 --- --- 1.1 ± 0.2 0.05 ± 0.01
60 Hz 60 Pulses 0.8 ± 0.3 5.0 ± 0.5 0.17± 0.07 --- --- 1.1 ± 0.4 0.05 ± 0.01
60 Hz 120 Pulses 1.3 ± 0.2 5.3 ± 0.2 0.26 ± 0.06 −1.2 ± 0.2 90 ± 10 2.5 ± 0.4 0.09 ± 0.01
60 Hz 240 Pulses 2.8 ± 0.3 5.5 ± 0.3 0.53 ± 0.07 −1.1 ± 0.2 80 ± 10 4.0 ± 0.4 0.17 ± 0.03
Lactate
Stimulation Parameters Maximum Concentration (mM) Peak Time (sec) Rise Rate (mM/sec) Fall Under Baseline (mM) Time Below Baseline (sec) Total Range (mM) Rate of Decrease (mM/sec)
30 Hz 120 Pulses 0.62 ± 0.09 6.3 ± 0.9 0.11 v 0.02 --- --- 0.6 ± 0.1 0.04 ± 0.03
60 Hz 60 Pulses 0.58 ± 0.06 5.00 ± 0.08 0.13 ± 0.02 --- --- 0.7 ± 0.1 0.03 ± 0.01
60 Hz 120 Pulses 1.1 ± 0.2 6.3 ± 0.4 0.17 ± 0.02 −0.2 ± 0.3 50 ± 20 1.3 ± 0.2 0.06 ± 0.01
60 Hz 240 Pulses 1.3 ± 0.2 7.6 ± 0.4 0.16 ± 0.01 −0.36 ± 0.02 50 ±10 1.6 ± 0.1 0.056 ± 0.003