Table 1.
CC FD% R1 | CC FD% R2 | ∆ (R1 – R2) | P Value | |
---|---|---|---|---|
MNV cases | 54.93 ± 5.70* | 50.18 ± 5.70* | 4.75 ± 4.58 | <0.0005* |
Normal Controls | 42.07 ± 4.60** | 40.49 ± 4.96** | 1.34 ± 1.19 | <0.0005** |
P value (t-test) | <0.0005 | <0.0005 | <0.001 | – |
In ring 1, the mean CC FD% measured 54.93 ± 5.70 and 42.07 ± 4.60 in the MNV and normal control group, respectively (P < 0.0005). In ring 2, mean CC FD% measured 50.18 ± 5.70 and 40.49 ± 4.96 in the MNV and normal control group, respectively (P < 0.0005). The mean difference of CC FD% between the two rings was statistically significantly greater in the MNV eyes compared with the controls: 4.75 ± 4.58 and 1.34 ± 1.19, respectively. R1 = ring 1, R2 = ring 2.