Skip to main content
. 2020 Jul 8;99(7):598–605. doi: 10.1159/000507265

Table 4.

Interobserver and intraobserver agreements (ICCs) for measuring lung and lobe volumes on CT in the supine and standing positions (n = 32 volunteers)

Interobserver agreements for measuring lung and lobe volumes (95% confidence interval)
Intraobserver agreements for measuring lung and lobe volumes (95% confidence interval)
supine standing supine standing
Total (bilateral) lung 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000)
Right lung 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000)
 Right upper lobe 0.999 (0.997–1.000) 0.994 (0.983–0.998) 1.000 (0.999–1.000) 0.994 (0.983–0.998)
 Right middle lobe 0.993 (0.980–0.998) 0.978 (0.940–0.992) 0.997 (0.991–0.999) 0.979 (0.942–0.993)
 Right lower lobe 1.000 (0.999–1.000) 1.000 (1.000–1.000) 1.000 (0.999–1.000) 1.000 (1.000–1.000)
Left lung 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000) 1.000 (1.000–1.000)
 Left upper lobe 0.999 (0.997–1.000) 0.999 (0.997–1.000) 0.999 (0.997–1.000) 0.999 (0.998–1.000)
 Left lower lobe 0.999 (0.998–1.000) 0.999 (0.998–1.000) 0.999 (0.998–1.000) 1.000 (0.999–1.000)