Table 3. Procedure outcomes of rotational atherectomy with IABP implant before PCI (RA with primary IABP) vs. RA with IABP implant during or after PCI (RA with bailout IABP) cases in the study period.
Variables | Both (N = 63) | Primary IABP (N = 51) | Bailout IABP (N = 12) | p-value* |
Acute no flow (N, %) | 0 | 0 | 0 | N/A |
Perforation (N, %) | 1 (1.6%) | 0 | 1 (8.3%) | 0.190 |
Wire transection (N, %) | 1 (1.6%) | 1 (2.0%) | 0 | 1.000 |
Profound/refractory shock | 3 (4.8%) | 0 | 3 (25.0%) | 0.006 |
Ventricular arrhythmia (N, %) | 2 (3.2%) | 1 (2.0%) | 1 (8.3%) | 0.347 |
Emergent CABG (N, %) | 0 | 0 | 0 | N/A |
Die on table (N, %) | 0 | 0 | 0 | N/A |
Acute CIN (N, %) | 17 (27.0%) | 12 (23.5%) | 5 (41.7%) | 0.279 |
* RA with primary IABP vs. RA with bailout IABP.
CIN, contrast-induced nephropathy. Abbreviations are in Table 1.