Table 3.

Acquisition parameters of MR sequences. n/a—not applicable, ax—axial, sag—sagittal, cor—coronal, mid-sag—mid-sagittal. *Indicates the total duration of all three sequences.

PDW T1 T1ρ T2 T2*
Sequence type Turbo-spin echo (2D) Inversion-recovery (2D) Spin-lock multi-gradient echo (3D) Multi-spin echo (2D) multi-gradient echo (2D)
Orientation ax, sag, cor mid-sag sag mid-sag mid-sag
Repetition time (ms) 1,500 3,000 30 1,500 700
Echo time (ms) 11.2 10.1 3.8 n × 8.4 (n = 1–12) 3.3 + n × 5.2 (n = 0–14)
Turbo spin-echo factor 6 5 44 12 15
Field of view (mm) 62 × 62 62 × 62 52 × 52 52 × 52 52 × 52
Acquisition matrix 144 × 142 224 × 220 176 × 176 176 × 176 176 × 176
Reconstruction matrix 256 × 256 224 × 224 224 × 224 224 × 224 224 × 224
Flip angle (°) 90 90 11 90 90
Number of signal averages 2 1 4 2 3
Slices 10 1 7 1 1
Slice Thickness / Gap (mm) 1.0 / 0.5 2.0 / n/a 3.2 2.0 / n/a 2.0 / n/a
Inversion times (ms) n/a 150, 300, 500, 800, 1,000, 1,500 n/a n/a n/a
Spin-lock durations (ms) n/a n/a 0, 10, 20, 30, 40 n/a n/a
Duration (min:s) 7:03 (*) 7:12 14:30 4:29 03:08