Supplemental Table 1.
Reliability of grip strength and isokinetic peak torque.
| Baseline Mean1 | CV2 | r3 | p-value4 | |
|---|---|---|---|---|
| Grip Strength | 44.7 ± 15.9 kg | 4.4 | 0.04 | 0.96 |
| Ext. Peak Torque 60°/sec | 150.1 ± 55.2 Nm | 6.8 | 0.08 | 0.89 |
| Ext. Peak Torque 180°/sec | 103.3 ± 31.2 Nm | 5.8 | 0.09 | 0.83 |
| Ext. Peak Torque 300°/sec | 80.8 ± 22.2 Nm | 6.2 | 0.12 | 0.78 |
| Joint Laxity | 5.8 ± 1.8 mm | 4.3 | 0.01 | 0.99 |
ata are means ± SD at the baseline visit.
Percent coefficient of variation.
Correlation-coefficient for the relationship between outcome measures and visit.
P-value for the correlation between outcome measures and visit number.