Table 3.
Feasibility of image acquisition and data-analysis
Target structure | Analyzing method | Feasibility n (%) |
---|---|---|
Left ventricular morphology and function | Linear Measurement | 54/54 (100%) |
Teichholz volume calculation | 54/54 (100%) | |
Devereux mass calculation | 54/54 (100%) | |
Biplane volume calculation | 53/54 (98%) | |
Longitudinal strain analysis | 53/54 (98%) | |
Rotational deformation analysis | 42/54 (78%) | |
Doppler data analysis | 54/54 (100%) | |
RV Morphology and function | Linear Measurement | 49/54 (91%) |
Doppler data analysis | 43/54 (79%) | |
Morphology and Function of Aortic valve, root and arch | Linear Measurements | 51/54 (94%) |
Doppler data analysis | 54/54 (100%) | |
Coronary anatomy and flow | 2D-Visualization of | |
RCA ostium | 54/54 (100%) | |
Proximal RCA | 53/54 (98%) | |
Distal RCA | 48/54 (89%) | |
LMCA Ostium | 53/54 (98%) | |
Proximal LAD | 49/54 (91%) | |
Color-Doppler Visualization of | ||
Distal LAD | 47/54 (87%) | |
Distal RCA | 46/54 (85%) | |
Distal RCX | 41/54 (76%) | |
pw-Doppler acquisition of | ||
Distal LAD | 44/54 (81%) | |
Distal RCA | 43/54 (80%) | |
Distal RCX | 40/54 (74%) |