Characteristics of the motion traces generated for each subject case. The parameters are in reference to Eq. (1). The fitting parameter (n) was 2 for all cases in this table. The X and Y directions were always in phase (φX = 0). The RMS displacement from the origin is a metric used to describe the 3D magnitude of motion from the phantom origin location (where it was registered). With motion tracking turned off, δRMS for each case in Table 3 would be equal to this value.

AY (mm) AZ (mm) AX (mm) RMS displacement from origin (mm) T (s) φZ (%)
Lung 1 16 10 6 6.9 5 20
Lung 2 5 10 9 5.4 5 −10
Lung 3 7 14 13 7.4 5 −20
Lung 4 12 13 13 8.0 5 0
Lung 5 10 6 2 5.6 5 0
Liver 1 9 2 1 3.4 3 −50
Liver 2 11 14 5 6.8 4 −60
Liver 3 16 5 1 6.1 4 10
Liver 4 18 16 6 9.4 3 0
Pancreas 1 13 3 1 5.4 3 20
Pancreas 2 14 11 5 6.8 5 −50
Pancreas 3 14 3 1 5.3 4 −10
Pancreas 4 10 6 6 5.1 4 −20