Skip to main content
. 2013 Aug 14:549–571. doi: 10.1007/978-3-642-39374-7_10

Table 10.2.

Comparison of self-purification time between the calculation value and the measured value

No. n (h−1) N 0 (test value) (#/L) N (calculated value) (#/L) Inline graphic nt t(calculated value) min t(test value) min
1 28.1 2.6 × 104 22 1.18 × 103 765 27 26
2 29 1 × 104 16 6.3 × 102 670 23 24
3 67 5.4 × 104 14 3.85 × 103 775 12 18˜20
4 59 4.5 × 104 16 2.8 × 103 750 13 15˜27
5 21 2 × 104 22 9 × 102 680 33 33˜38
6 21 6 × 103 22 270 620 30 30˜35
7 70 9 × 104 9.5 9.5 × 103 830 12 8˜15
8 185 5.8 × 104 3.8 1.5 × 104 850 4.6 19
9 36 7 × 104 28 2.5 × 103 748 21 14
10 72 7 × 104 14 5 × 103 780 11 11.5
11 120 7 × 104 9.8 7.2 × 103 810 6.7 6.5
12 150 7 × 104 8 8.7 × 103 820 5.5 5.5
13 180 7 × 104 6.8 1.1 × 104 830 4.7 3
14 230 7 × 104 5.4 1.3 × 104 850 3.6 3
15 25 1.1 × 103 10 1.1 × 102 560 22 16
16 50 8.5 × 102 10 0.85 × 102 540 11 10
17 40 105 200 5 × 102 650 16 30
18 29 1.06 × 105 15 7 × 103 810 28 30