Skip to main content
. 2013 Aug 14:377–465. doi: 10.1007/978-3-642-39374-7_8

Table 8.12.

Influence with no airshower process

Air cleanliness level Average particle concentration (pc/L) Air change rate (h−1) Particle generation rate (pc/h) Increase of particle concentration for each liter of air (pc) Increase of particle concentration (%) Variation of air cleanliness level
100,000 2000 15 5.4 × 107 144 7.2 100,000
10,000 200 25 5.4 × 107 86.4 43.2 10,000
1,000 20 50 5.4 × 107 43.2 216 10,000
100 2 450 5.4 × 107