Table VII.

Frequency of detection of SARS-CoV-2 RNA on personal protective equipment (PPE) of healthcare workers

Type of ward (country) Types of sampled surfaces (N) Proportion of virus detection Mean virus concentration (log10 cps) Reference
ICU with COVID-19 patients (China) Shoe sole (6) 50% 4.5 [138]
Glove (4) 25% 4.5
Sleeve cuff (6) 17% 4.9
Face shield (6) 0%
General ward with COVID-19 patients (China) Shoe sole (3) 0% [138]
Glove (3) 0%
Sleeve cuff (3) 0%
Face shield (3) 0%
COVID-19 isolation room (Singapore) Face shield (1) 0% [210]
N95 mask (1) 0%
Waterproof gown (1) 0%
COVID-19 isolation room (Singapore) Different surfaces from PPEs (30) 0% [222]
COVID-19 isolation room (Singapore) Different surfaces from PPEs (10) 10% (front of shoes) Ct value of 38.96 [186]
Different wards in grade III hospital (China) Hand sanitizer dispenser (59) 20.3% Unknown [216]
Glove (78) 15.4%
Eye protection or face shield (58) 1.7%
COVID-19 negative pressure isolation room (South Korea) Different surfaces from PPEs (133) 11.3%∗∗ Unknown [223]

cps, copies per swab.

Indicating a low viral RNA load.

∗∗

Mainly on the top of the head and the foot dorsum.