Skip to main content
. 2020 Sep 18;426:213544. doi: 10.1016/j.ccr.2020.213544

Table 16.

The various MOF derived filters for removal of particulate matters (PMs).

MOF filters PM2.5
PM10
Ref
Efficiency (%) Temperature (°C) Efficiency (%) Temperature(°C)
PPC/ZIF-8 91.68 ± 0.57 [229]
Ag-MOFs@CNF@ZIF-8 94.3 >95 [234]
PAN-ZIF-8 99.97 (PM0.3) ≥99.99 [230]
ZIF-8/rGA 99.3 25 99.6 25 [231]
ZIF-8/rGA >98.8 200 >99.1 200 [231]
polyimide/ZIF-8 96.6 ± 2.9 300 300 [235]
MIL-53(Al)–NH2@PAN 99.99 (PM0.3) [236]
PLA-ZIF-8 (PZD5) 94.44 96.57 [237]
ZIF-67@PAN 87.2 [238]
ZIF-8/PAN 88.33 ± 1.52 89.67 ± 1.33 [233]
CNFs/HKUST-1/stainless steel screen >95 25 25 [239]
H-ZIF-L_PP 92.5 ± 0.8 25 99.5 ± 0.2 25 [240]
UiO-66-NH2@CNTs/PTFE 99.99 (PM0.3) [241]
ZIF-8@Melamine foam-3rd 99.5 ± 1.7 150 99.3 ± 1.2 150 [232]
ZIF-8@Nonwoven fabric-3rd 99.9 ± 0.2 150–250 99.7 ± 0.1 150–250 [232]
ZIF-8@Glass cloth-3rd 96.8 ± 1.3 200 95.8 ± 1.4 200 [232]
ZIF-8@Metal mesh-3rd 92.1 ± 0.7 300 91.3 ± 0.4 300 [232]
ZIF-8@Plastic mesh-3rd 95.8 ± 1.3 80–100 94.1 ± 1.5% 80–100 [232]