Skip to main content
. Author manuscript; available in PMC: 2020 Sep 18.
Published in final edited form as: IEEE Trans Appl Supercond. 2014 Oct 16;25(3):4301205. doi: 10.1109/tasc.2014.2363496

TABLE I.

L500 (11.74 T)

Operating temperature [K] 4.2–6.0
Cold bore for H800 [mm] 237
Over all diameter; height [mm] 780;1422
Magnet mass [kg] 1200
Magnetic energy @ Iop=246 A. [MJ] 4.6
Temporal stability [ppm/hr] < 0.01
Measured field homogeneity [ppm] 0.45*
*

17-mm diameter × 30-mm length.