TABLE IV.

KEY PARAMETERS OF SHAKING MAGNET FOR 1.3 G

M C1 C2 C3 C4
Winding 2α1 (i.d.) [mm] 600
Winding 2α2 (o.d.) [mm] 602.1 600.7 603.5 600.7 600.7
b1 [mm] −48.3 48.3 108.2 158.9 320.0
b2 [mm] 48.3 108.2 158.9 320.0 407.5
# turns/layer; # layers 21; 3 13; 1 11; 5 35;1 19;9
Total conductor length [m] 1160
Magnet inductance [mH] 126
Bsh @Iop = 98 A [mT] 60
Bsh field error @Iop [%] < 0.3(500-mm DSV)
One wave cycle period [hr] 4(=1↑+1↓+l↑+1↓)
Shaking period [day] ~17 [= (4 hr/cycle) × 100 cycles]