Average temperature linear regression parameters a for 2 sensors of each type at AIRS during ambient monitoring.

Sensor Temperature Collocation Dates N (hr) Slope Intercept R2 MBE (°C) NRMSE (%) PDavg (%)
AQY 8/9/18–12/3/18 1197 1.19 −2.29 0.98 * 1.83 12 1.1
PA 8/10/18–4/30/19 5454 0.9 7.2 0.91 * 5.23 34 6.1
RAMP 12/12/18–7/31/19 4893 1.14 −0.83 0.96 * 1.36 19 4.8

a PM2.5 sensor = Intercept + Slope PM2.5 reference, * Statistically significant at p < 0.01.