Skip to main content
. 2020 Aug 25;20(17):4796. doi: 10.3390/s20174796

Table 5.

Comparison statistics and linear regression parameters a for each data set.

Sensor Location N (hr) Slope Intercept r2 MBE (µg/m3) NRMSE (%)
AQY AIRS—Ambient 2815 0.84 −0.14 0.45 * −1.39 53
AIRS—Prescribed Fire - - - - - -
Natchez 181 2.18 −7.89 0.86 * 63.89 146
Pole Creek 63 0.54 0.87 0.77 * −1.18 45
Alder Pinehurst 136 1.35 1.40 0.52 * 5.91 82
PA
(CF = atm)
AIRS—Ambient 4750 1.61 −1.46 0.87 * 2.98 66
AIRS—Prescribed Fire 10 1.61 −2.49 1.00 * 6.16 70
Natchez 367 1.20 15.23 0.96 * 32.82 44
Pole Creek 88 0.93 0.36 0.74 * 0.13 50
Alder Pinehurst 161 1.30 9.78 0.62 * 13.79 117
PA
(CF = 1)
AIRS—Ambient 4750 1.63 −1.58 0.87 * 3.00 48
AIRS—Prescribed Fire 10 2.44 −7.97 0.99 * 12.36 154
Natchez 367 1.85 18.41 0.96 * 91.17 125
Pole Creek 88 0.93 0.36 0.74 * 0.13 50
Alder Pinehurst 161 1.81 4.76 0.62 * 15.67 145
RAMP AIRS—Ambient 3493 0.89 2.58 0.91 * 1.83 37
AIRS—Prescribed Fire 10 1.35 −0.05 0.99 * 4.89 15
Natchez - - - - - -
Pole Creek - - - - - -
Alder Pinehurst 107 0.77 6.61 0.69 * 3.69 5
Alder Springville 802 1.48 −2.48 0.85 * 14.47 3

a PM2.5 sensor = Intercept + Slope PM2.5 reference * Statistically significant at p < 0.01.