Skip to main content
. 2020 Aug 22;20(17):4749. doi: 10.3390/s20174749

Table 10.

Classification accuracy of the proposed methods and other resent methods for BCI Competition IV Dataset I.

Methods 1a 1b 1c 1d 1e 1f 1g Mean ± Std
PELM [70] (2018) 79.00 56.50 59.50 73.00 71.50 64.50 85.00 70.00 ± 10.33
LRFCSP [71] (2019) 87.40 70.00 67.40 92.90 93.40 88.80 93.20 84.70 ± 11.22
OPTICAL [72] (2019) 87.32 61.67 71.83 88.17 89.00 85.83 93.83 82.53 ± 8.17
BF [73] (2020) 86.24 88.31 92.89 89.51 90.92 88.46 90.16 89.50 ± 2.12
SCSP-RDA [74] (2020) 97.00 96.00 72.50 75.00 78.50 96.00 95.50 87.21 ± 11.26
CSP-Wavelet+LOG 67 69 76 97 97 90 94 84.29 ± 12.26
CSP-WPD+LOG 64 69 80 95 100 93 94 85.00 ± 13.05
CSP-FB+LOG 73 75 87 98 99 93 97 88.86 ± 10.12