Skip to main content
. 2020 Aug 26;20(17):4830. doi: 10.3390/s20174830

Figure 18.

Figure 18

Stress and strain in the undamped stack when subjected to 1.2/50 µs 45 kV positive (left) and negative lightning impulses (right). The tensile stress limit of 10 MPa is marked by a black dotted line. (The terminal voltage is the voltage applied to the top electrode of the stack.).