Imaging parameters for T1-,T2- and contrast-enhanced T1-weighted MRI and SS-EPI, and RESOLVE DWI sequences

Parameters T1WI Fat-suppressed T2WI Contrast-enhanced T1WI SS-EPI DWI Resolve DWI
(RS-EPI) DWI
Scan plane axial axial sagittal coronal axial sagittal coronal axial axial
Slice thickness, mm 4 4 4 4 4.5 4 4.5 4 4
Slice gap, mm 0.4 0.4 0.4 0.4 0.45 0.4 0.45 0.4 0.4
TR, ms 500 5460 4450 5460 507 582 500 6800 5700
TE, ms 12 87 87 87 12 9 9 113 78
Matrix 320 × 320 320 × 320 320 × 320 320 × 320 320 × 320 320 × 320 320 × 320 192 × 192 200 × 200
FOV, mm 300 × 300 300 × 300 280 × 280 280 × 280 240 × 240 240 × 240 260 × 260 300 × 300 300 × 300
Flip angle 160° 148° 156° 148° 160° 180° 180°
b value, s/mm2 0; 1000 0; 1000
Average 2 2 2 2 2 2 2 2 2
Scan times 2min14s 2min37s 2min44s 2min14s 2min52s 3min32s 3min14s 2min9s 4min59s

MRI magnetic resonance imaging, SS-EPI single-shot echo-planar imaging, RESOLVE readout segmentation of long variable echo-trains, DWI diffusion-weighted imaging, T1WI T1-weighted imaging, T2WI T2-weighted imaging, RS-EPI readout-segmented echo-planar imaging, TR time of repeat, TE time of echo, FOV field of vision, min minutes, s second