Skip to main content
. 2020 Mar 23;102(14):e81. doi: 10.2106/JBJS.19.01027

TABLE II.

Displacements at Predetermined Measurement Points Under 75 to 750-N Loading Tests

Paired Markers Group P Value
Infrapectineal QLS Buttress Plate* Suprapectineal QLS Buttress Plate* Suprapectineal Reconstruction Plate with Long Screws* Infrapectineal Reconstruction Plate with Long Screws*
1-2 0.12 (0.05 to 0.26) 0.21 (0 to 1.08) 0.11 (0.06 to 0.18) 0.16 (0.09 to 0.30) 0.295
3-4 0.10 (0.02 to 0.14) 0.45 (0.05 to 0.62) 0.23 (0 to 0.29) 0.10 (0.01 to 0.65) 0.297
5-6 0.27 (0.11 to 0.49) 0.03 (0 to 0.36) 0.15 (0.01 to 0.55) 0.17 (0.03 to 0.24) 0.120
7-8 0.07 (0.03 to 0.66) 0.15 (0.01 to 0.43) 0.04 (0.01 to 0.14) 0.09 (0.01 to 0.25) 0.657
7-9 0.14 (0.02 to 0.38) 0.17 (0.07 to 0.44) 0.17 (0.02 to 0.19) 0.14 (0.01 to 0.23) 0.846
7-10 0.15 (0.01 to 0.55) 0.09 (0.02 to 0.89) 0.07 (0.04 to 0.24) 0.06 (0.02 to 0.15) 0.912
*

The values are given as the median in millimeters, with the range in parentheses.

Multiple-group comparisons were performed with use of the Kruskal-Wallis test with a significance level of p = 0.05.