Skip to main content
. 2020 Sep 12;5(37):23502–23509. doi: 10.1021/acsomega.0c00417

Table 1. Comparison of Analytical Performance of Fabricated HMCA/NF Sensing Electrode with Other Proposed Nonenzymatic Sensors.

sensing materials detection potential (V) sensitivity (μA mM–1 cm–2) LOD (μM) linear range response time (s) references
3D electrospun CuO nanofibers/GCE 0.4 431.3 0.8 6 μM to 2.5 mM ∼1 (36)
ZnO–CuO HNCs/FTO glass plate 0.7 3066.4 0.21 0.47 μM to 1.6 mM ∼2 (37)
β-MnO2 micro/nanorod arrays/flexible carbon            
fiber fabric 0.55 1650.6 1.9 0.01 mM to 4.5 mM <3 (38)
CuO            
nanoparticles/CNT 0.4 2596 0.2 0.4 μM to 1.2 mM <1 (39)
Ni/MnO2            
nanocomposite/GCE 0.45 1040 0.1 0.25 μM to 3.5 mM <3 (40)
CuO nanoparticles decorated carbon spheres 0.55 2981 0.1 0.5 μM to 2.3 mM <5 (41)
Nafion/CuO nanoseeds/Au 0.6 1101 50 0.1 mM to 13.3 mM ∼2 (42)
3D porous CNT/MnO2 composite 0.6 3406.4 0.5 5 μM to 1 mM <3 (43)
ZnO@N2-doped carbon sheets (NDC) 0.75 231.7 6.3 0.2–12 mM <3 (44)
HMCA/NF 0.3 2194 0.43 5 μM to 2.5 mM <4 present work