Skip to main content
. 2019 Jun 23;21(6):619. doi: 10.3390/e21060619

Table 4.

Parameters measured and the uncertainties of main parameters.

Parameter Instrument Measurement Range Uncertainty
Temperature WZPK2 −200 to 600 °C ±(0.3 + 0.5% |t|) °C
Pressure dTRANS 0–25 bar ±0.2%
Electric power Smart energy meter N/A ±0.5%
W˙turb ±8.27%
P3/P4 ±0.29%
η carn ±0.95%
η gros ±6.1%
η i s,turb ±6.4%
η elec–mech ±8.3%
η over_tg ±10.5%