Table 4.
Parameters measured and the uncertainties of main parameters.
| Parameter | Instrument | Measurement Range | Uncertainty |
|---|---|---|---|
| Temperature | WZPK2 | −200 to 600 °C | ±(0.3 + 0.5% |t|) °C |
| Pressure | dTRANS | 0–25 bar | ±0.2% |
| Electric power | Smart energy meter | N/A | ±0.5% |
| ±8.27% | |||
| P3/P4 | ±0.29% | ||
| η carn | ±0.95% | ||
| η gros | ±6.1% | ||
| η i s,turb | ±6.4% | ||
| η elec–mech | ±8.3% | ||
| η over_tg | ±10.5% |