Skip to main content
. 2020 Sep 11;8:525. doi: 10.3389/fped.2020.00525

Table 2.

Performance measures of the sepsis model.

Measure Physician's sepsis diagnosis (95% confidence interval) ANN sepsis diagnosis (95% confidence interval)
Accuracy 73.33% (54.11–87.72%) 86.66% (69.28–96.24%)
Precision 65.22% 82.35%
Sensitivity 100% (78.20–100.00%) 93.33% (68.05–99.83%)
Specificity 46.67% (21.27–73.41%) 80% (51.91–95.67%)
AUROC p-value 73.33% (54.75–91.91%)
0.0295
94.44% (85.68–100.32%)
<0.0001
Standard error 0.0947 0.04373
Positive predictive value 65.22% (53.87–75.06%) 82.35% (62.70–92.83%)
Negative predictive value 100% 92.3% (63.98–98.78%)