Table 3.

Parameters for IORT electron beam procedure in primary locally advanced rectal cancer.

IORT Parameters
Target volumen description
  • -

    Tumour residue (R0, R1, R2)

  • -

    Normal tissues exposed

  • -

    Normal tissues protected/mobilized

  • -
    Special conditions:
    • Vascular manipulation
    • Others
IORT factors
  • -
    Applicator size /diameter
    • Bevelled end (degrees)
  • -
    Electron energy
    • Isodose prescription
  • -

    Total dose

  • -
    Number of fields
    • Report every parameter for every field
    • Overlapping (yes / no)
    • Field–within-a-field (description)
  • -

    Protections

  • -

    Fluid stability

  • -

    Time of beam on

  • -

    Gantry angulation

  • -

    In vivo dosimetry (system/site measured)

Integrated pre-IORT treatment factors
  • -
    Surgery: type of resection (R0, R1, R2)
    • Quality of Total Mesorectal Excision (TME)
  • -
    Preoperative
    • Chemoradiation (CRT) (short vs long course)
    • Induction chemotherapy + CRT (short vs long course)
  • -
    Postoperative
    • CRT
    • CRT + adjuvant chemotherapy