Skip to main content
. 2020 Sep 28;69:101265. doi: 10.1016/j.pmcj.2020.101265

Table 6.

Details of parameters settings in the simulation.

Parameter symbol Parameter description Value
R Data transfer rate 1 Mbps
C The light speed 3×108m∕s
MDefault Number of default measurements 209
tDistributingActivityIntervals Time of distribution of activity intervals 0.32 ms
nSensorNode Number of sensor node 4
nSinkNode Number of sink node 1
EInitialSensorNode Initial energy of sensor node 0.3 J
EInitialSinkNode Initial energy of sink node 0.525 J
BPL Body path loss 3.2 dB
EDefault Default entropy level 0.915 Bits
CRDefault Default compression ratio 0.8164
N Total number of unknowns in RN 256
tLightweightSecureSensing Time of lightweight secure sensing 0.0145 s
EUsageEnergyLightweightSecureSensing Usage energy of lightweight secure sensing 0.028 mj
Erx-elec Reception energy dissipation 36.1 nj/bit
Etx-elec Transmission energy dissipation 16.7 nj/bit
EAdd Energy dissipation for addition 3.3 nj
EMrd Memory read energy dissipation 0.26 nj
EMwr Memory write energy dissipation 4.3 nj
EMul Multiplication energy dissipation 9.9 nj
ESft Shift energy dissipation 3.3 nj
ECmp Comparison energy dissipation 3.3 nj
X Vector representing acquired signal It is calculated dynamically
SXDefault Number of nonzero coefficients (Default sparsity level) 17
φ Measurement matrix in RM×N It is calculated dynamically
Y Measurements in RM It is calculated dynamically
PAcqired Sensing power consumption 15.01 mW
tInstructionExecution Instruction execution duration 0.135 μs
tActiveListeningPeriod Active listening period 0.02 s
fOperation Operation frequency 7.4 MHZ
PSActivityIntervals Packet size of activity intervals 48 bit
tNormalSensing Time of normal sensing 0.346 ms
EUsageNormalSensing Usage energy of normal sensing 0.5 μj
PBCK Background power consumption 9.6 mW
PACQ Sensing power consumption 15.01 mW
tDSCBSensing Time of DSCB sensing 0.0180 s
EUsageDSCBSensing Usage energy of DSCB sensing 1 mj